A ProfileSystem exists with a connection on its end port that is split - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

PPMProductFamily
3D Design and Visualization
PPMProduct
Intergraph Smart 3D
PPMCategory
Administration
Version_S3D
11.x(2016)

Message

A ProfileSystem exists with a connection on its end port that is split.

Severity

Crucial.

Detailed Description

A profile system exists with a connection on its end port that is split.

Possible Cause

A profile bounded by a plate that is split at the same location as the end port of the profile.

Possible Impacts

None.

What You Should Do

  1. Open the model.

  2. In the Molded Forms task, remove the split end connections.

  3. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  4. If the object is still posted, contact Smart 3D Support. If possible, explain how to duplicate the situation.