Meaning: A flow direction inconsistency exists where either two runs meet with opposite flows, a branch exists where all connected runs flow in the same direction, or a run flows into an equipment nozzle that has an opposite flow.
Recovery:
-
Open the Piping task.
-
Click Select .
-
Set the Locate Filter to Piping Runs.
-
Select the pipe and note the flow direction.
-
Select the other pipe and note the flow direction.
-
After determining which flow direction needs to be corrected, select that pipe run.
-
Click on one of the flow direction arrows.
-
In the Flow ribbon that appears, select the correct flow direction.