Meaning: The software failed to create or modify the plane by elements object. The specified constraint type is not applicable for the current configuration. For example:

  • Requesting a perpendicular support for a two-sided bracket is not allowed.

  • The geometry of the support cannot provide a wire geometry.

  • A perpendicular support must have wire geometry for a three-sided bracket.

Recovery

  1. Select supports that will be applicable to the required constraints.

  2. Update any supports that are on the To Do List.

  3. If a perpendicular constraint is required, use a three-sided bracket in which one of the supports can supply a wire geometry.

  4. If problem still exists, report steps taken to your support group.