Error from name rule - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: This error is a generic failure that occurred when computing the name rule semantic. Review the error log to find out the actual cause of the failure. Some common causes are:

  • The name generator is not working

  • The name rule was deleted from the catalog

  • Access permissions are not set to allow the name rule to run.

Recovery:

  1. Turn on error logging. For more information, see Troubleshooting the Software in the Installation Guide.

  2. Refer to the error log for a detailed description.

  3. If name generator is not working, see Configure the Name Generator Service in the Installation Guide for repair instructions.

  4. If there are any permission problems, provide proper permission to those objects.

  5. If the name rule holder was deleted from the catalog, select another name rule in the object's Properties dialog box.