Unable to compute equipment weight and CG values due to a child object having a weight or CG value that is undefined. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The equipment's weight and center of gravity could not be computed because one or more of the components that define the equipment do not have the weight or center of gravity values defined for them.

Recovery:

  1. Set the Locate Filter to Equipment Component.

  2. Select each of the equipment components that define the designed equipment.

  3. Click Edit > Properties.

  4. On the Occurrence tab, select Weight and CG from the Category drop down.

  5. Verify that the weight and center of gravity values are defined.

  6. Click OK.