Meaning: The controlling piping specification does not have weld clearance rule information defined. Weld graphics are not generated unless the clearance information is defined.

Recovery: In the piping specification, add weld clearance rule information. Refer to the "Weld Clearance Rule Sheet" section of the Piping Reference Data Guide for more information.