Ladder is missing the top edge reference object. Edit ladder and select a new top edge. The ladder will not respond to any edits until a new top edge is selected. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The top edge reference object that was specified when the ladder was created has moved or no longer exists in the model. The top edge reference is used to define the top elevation of the ladder. The ladder will not respond to property edits until you select a new top edge.

Recovery:

  1. Click Select , and select the ladder.

    TDL Select Ladder

  2. Select Select Top Edge on the ribbon.

  3. Select a new top edge reference for the ladder.

    TDL STRUCT Select Top Edge for Ladder TDL STRUCT Fixed Ladder Top Edge