Axis-end frame connection is related to something other than a supporting member system. Change connection to unsupported and then re-select the supporting member. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The axis-end member's supporting member input is not a member system, resulting in improper placement of the axis-end connection. This error is an internal software failure where the software did not properly call the frame connection with its required inputs.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error.

  5. Select By Rule from the Connection box on the ribbon.

  6. Redefine the end location of the member.