Meaning: The trench run does not meet the minimum bottom slope criteria as specified in the catalog.

Recovery:

  1. In the Workspace Explorer, select the trench run that is in error.

  2. Click Properties .

    The Trench Run Properties dialog box displays.

  3. On the General tab, select Dimensions in the Category box.

  4. Change the Elevation or Slope values.

  5. Click OK.

  6. Click Finish on the command ribbon.

-OR-

  1. In the Workspace Explorer, select the trench run that is in error.

  2. Click Path .

  3. Modify the Sketch 3D path so that it meets the bottom slope criteria as specified in the catalog.