Unable to apply cutout. Please revise header run. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The width of the branch trench run is large enough to cut one of the trench part's geometry in the header trench run.

Recovery:

  1. In the Workspace Explorer, select the header trench run whose trench feature is in error.

  2. Click Path .

  3. Modify the Sketch 3D path so that the width of the branch trench run is less than the sketch segment of the trench feature.

  4. Click Finish on the path ribbon, and then click Finish on the command ribbon.

-OR-

  1. In the Workspace Explorer, select the branch trench run that is in error.

  2. Click Properties .

    The Trench Run Properties dialog box displays.

  3. On the Start Cross-Section tab, select Dimensions in the Category box.

  4. Decrease the Inside Left Width or Inside Right Width value so that the width of the branch trench run is less than the segment length of the header trench feature.

  5. Click OK.

  6. Click Finish on the command ribbon.