Symbol failed. <additional information> - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: This message indicates that a failure occurred in a Smart 3D symbol where the outputs or shape of the symbol could not be constructed. The symbol provided additional information indicating what problem occurred and what needs to be done to resolve this issue. If the resolution of this issue is unclear, then please contact your administrator.

Recovery: Typically, there is an issue with one or more inputs which drive the construction of the symbol outputs or shape. This might include a property whose values are outside the range of valid values (for example, a dimensional value that is less than zero); or it might be an input geometry object that does not satisfy the required conditions (for example, an identified surface that is vertical rather than horizontal). Adjusting the inputs and input values resolves most of these issues.

  • These types of messages can either be warnings or errors. In the case of a warning, the symbol constructed outputs or shape might be updated based on the provided inputs; whereas an error indicates that the outputs or shape will not be updated.

  • An example of this error would be: “Symbol failed. Equipment vessel diameter must be greater than 0.0.” This error indicates that the vessel diameter property must be set to a non-zero positive value.