Meaning: Either the supported member (and its end port) or the surface port were not provided as inputs into the construction/compute of the assembly connection, resulting in incorrect placement of the general surface connection. This error is an internal software failure.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Member Assembly Connections.

  4. Select the assembly connection in error.

  5. Click Delete Delete CLASSIC ICON.

  6. Click Place Assembly Connection .

  7. Select the frame connection.

  8. Clear the By Rule option.

  9. Select More from the Type box.

  10. Select Member End Assembly Connection > General Surface Assembly Connection > GeneralSurfaceAsmConn_1.

  11. Click OK.

  12. Click Finish.