Combined footings require a minimum of two supported members. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: This can be caused by:

  • A copy/paste operation where the combined pier slab footing is pasted and the same supported member part is selected twice.

    -OR-

  • Members input into the footing are deleted to less than the two members required to define the footing.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Footings.

  4. Select the footing that is in error.

  5. Click Select member(s) on the ribbon bar.

  6. Select all the member systems that should be part of this footing.

  7. Click Finish.

Another option is to delete the footing.