Profile system split was stopped because delay is on for Molded Forms - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Object Type in the To Do List: Profile system.

Meaning: Compute of the profile system split could not complete because delay is on for Molded Forms.

Recovery:

  1. Click Tools > Delay Settings and clear Delay Molded Forms.

  2. Update any inputs that are on the To Do List.

  3. Update or recompute the profile system.

  4. If the problem persists, report steps taken to your support group.