Members are not constrained by the same joint. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: Members must share a common internal axis joint or the supported member is point-on with supporting member's axis joint. This error should never happen and is an internal software failure.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error.

  5. Select Unsupported from the Connection box. This action clears the frame connection in error.

  6. Select More from the Connection box.

  7. Select Axis Colinear > AxisColinear1, and click OK.

  8. Reselecting the supporting member.