The flow direction of one of the ports of this part is inconsistent with the flow direction of the run it belongs to. The flow direction of the run or the port should be modified to resolve the inconsistency. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The flow directions are inconsistent. You need to edit one of the flow directions to match the other flow direction.

Flow Direction 1Flow Direction 2

Recovery:

  1. Open the Piping task.

  2. Click Select .

  3. Set the Locate Filter to Piping Runs.

  4. Select the pipe and note the flow direction.

  5. Select the other pipe and note the flow direction.

  6. After determining which flow direction needs to be corrected, select that pipe run.

  7. Click on one of the flow direction arrows.

  8. In the Flow ribbon that appears, select the correct flow direction.