Axis-collinear frame connection is missing a required input. Change connection to unsupported and then re-select the supporting member. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The axis collinear frame connection expects three input objects: a supported member, a collinear supporting member, and the end port of the supporting member. This is an internal software failure where not all the inputs were provided to the collinear connection.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error.

  5. Select By Rule from the Connection box on the ribbon.

  6. Redefine the end location of the member.