Inconsistent Constraint - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The constraint is inconsistent with the other defined constraints on the object.

Recovery:

  1. Set the Locate Filter to Equipment.

  2. Select the equipment in error.

  3. On the ribbon, delete the inconsistent constraint. For more information on the available relationship constraints, see Set positioning relationships for equipment in the Equipment and Furnishings User's Guide.