Two or more boundary conditions are attached to the same frame connection or coincident frame connections. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: Two or more boundary conditions are defined for the same location. Only one boundary condition is valid for an end of a member.

Recovery:

  1. Click Select .

  2. Set the Locate Filter to Boundary Conditions.

  3. Select all but one of the boundary conditions at that frame connection.

  4. Click Delete ICON Remove.