Centerline frame connection is using the same member system for both the supporting and supported member. Change connection to unsupported and then re-select the supporting member. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The centerline member and the supporting member are the same object, resulting in improper placement of the centerline connection. This error is an internal software failure where the calling software is attempting to make a member centerline with itself.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error.

  5. Select More from the Connection box on the ribbon.

  6. Click Centerline in the tree view.

  7. Select the centerline frame connection to use.

  8. Redefine the end location of the member.