Brace end is not located near the second supporting member in the vertical corner brace frame connection. Change the connection to unsupported and then re-select the supporting members. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: The X, Y, Z brace end coordinates are not located near the second supporting member. This is an internal software failure where the software allowed an improperly connected vertical corner brace.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error.

  5. Select By Rule from the Connection box on the ribbon.

  6. Redefine the end location of the brace by selecting the frame connection of the supporting beam.