Meaning: The member or surface has changed position in such a way that the cope is now invalid.

Recovery: Delete and replace the cope.

To delete the cope:

  1. Click Select .

  2. Select Structure in the Locate Filter.

  3. In the Workspace Explorer, expand the member prismatic part branch.

  4. Select the trim feature node under the member part branch to delete.

  5. Click Delete ICON Remove.

Then use Trim Member to replace the cope.