Splice connections do not support members with different rotations. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: Collinear members connected with a splice connection must have the same rotation and mirror value. One member was placed with a different rotation/mirror value or modified to have different values.

Recovery: Edit both collinear members to make their rotation and mirror values the same.

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Member Parts.

  4. Select one of the members.

  5. Note the Angle and Reflect settings on the ribbon.

  6. Select the other member and define the same Angle and Reflect settings for it.