Open the StructHandrail.xls workbook. This file is located in [Product Installation Folder]\CatalogData\BulkLoad\DataFiles.
-
Select the CustomInterfaces sheet.
-
Select a row after the Start keyword but before the End keyword, and click Insert > Row.
-
In the InterfaceName column, enter the Group Name that you assigned earlier.
-
In the AttributeName column, enter a name for the attribute.
-
In the AttributeUserName column, enter a description of the attribute name.
-
In the Type column, enter the data type.
-
In the UnitsType column, enter 0.
-
In the PrimaryUnits column, enter 0.
-
In the OnPropertyPage column, enter 1.
-
In the ReadOnly column, enter 0.
-
Repeat steps 5 through 11 as many times as necessary to include all attributes.
Below is an example of what the worksheet should look like when finished: