Option Switches 40-49 - PDS - Reference

Plant Design System (PDS) ISOGEN

PPMProductFamily
3D Design and Visualization
PPMProduct
PDS
PPMCategory
Reference
Version_S3D
12.x(2018)

Isometric Facility

Word #

Switch Position

File Marker or Data

Parameter Value Options

Spare

52

Weld Numbers

53

A

0

Weld Numbers OFF

1

Weld Numbers ON (small characters)

2

Weld Numbers ON (medium characters)

3

This Option Switch Position should be set to value 0, 1, 2, or 3 if Position 4 is set to value 0 or 1.

4

Weld Numbers ON (large characters)

5

Weld Numbers ON (small characters)

Only number fabrication welds

6

Weld Numbers ON (medium characters)

Only number fabrication welds

7

Weld Numbers ON (large characters)

Only number fabrication welds

8

Weld Numbers ON (small characters)

Only number erection welds

9

Weld Numbers ON (medium characters)

Only number erection welds

Weld Numbers ON (large characters)

Only number erection welds

Values 1-9 number welds consecutively, starting at 1, for the entire pipeline.

All of the above size values are only valid when Weld Numbers are being plotted in the original circular style enclosures.

This Option Switch Position should be set to value 0, 1, 2, or 3 if Position 4 is set to value 0 or 1.

B

0 or blank

Do not generate a weld box.

1

Generate a weld box.

2

For Operations Box Summary to be plotted / printed.

C

0 or blank

Welds numbers run consecutively, starting at 1, for the entire pipeline.

1

Weld numbers start at 1 on each new sheet generated for a pipeline.

2

Spool isometric Weld Numbers to match Full isometric Weld Numbers when using continuous Weld Numbers across drawings.

3

Spool isometric Weld Numbers to match Full isometric Weld Numbers when using the Weld Number commencing at 1 on each new drawing facility

D

0 or blank

Generate weld numbers for offshore welds

1

Generate weld numbers for offshore welds ONLY

2

Suppress weld numbers for offshore welds.

This Option Switch Position should be set to value 2 when Position 1 is set to value 4, 5, 6, 7, 8, or 9.

E

0 or blank

Single sequence for all welds.

1

Individual sequence for each weld type.

Weld Control

54

0

Std. is = 0 to have all welds plotted.

or set:

1

To have all welds suppressed.

2

To have only Site welds plotted.

3

To have only Fabrication welds plotted.

4

To change Site welds to Fabrication welds. This setting will not change User Inserted Site Welds.

Spare

56-57

Instrument Identification

59

Controls which 3D system parameter is used on the isometric for the identification of instruments.

0

Std. is = 0 for instrument NAME output.

or set:

1