End-Point Components - PDS - Reference

Plant Design System (PDS) ISOGEN

PPMProductFamily
3D Design and Visualization
PPMProduct
PDS
PPMCategory
Reference
Version_S3D
12.x(2018)

When a pipeline in the model changes name at a multi-connect point component then that component is "owned" by more than one line. When this occurs, the component is always assigned to the pipeline attached to connect point 1 of the component. For example, if three different lines come together and join at a tee, the tee component will extract onto, and show up in the B.O.M. of, the line at connect point 1 of the tee. When the other two lines are extracted, the tee will show up as dotted, no-MTO and will not appear in the B.O.M. (Notice that it is NOT necessary that piping segments in the model be "broken" in any way to achieve the above result.)