ManualDamper Sheet - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D HVAC Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
HVAC
Search by Category
Reference Data
Smart 3D Version
12 (2018)

The ManualDamper sheet in the HVAC.xls workbook defines the manual dampers available in the Catalog.

PartNumber

Type the part number assigned to the manual damper. The software uses the part number at placement when the part name is automatically generated. An example is PDS-100.

SymbolDefinition

Type the definition of the symbol that you are creating for the manual damper.

FaceWidth

Type the width of the face for the damper.

FaceDepth

Type the face depth for the damper.

ComponentType

Type the component type for the damper.

PartDescription

Type a description for the damper. An example is Manual Damper Part.

DryWeight

Type a dry weight for the damper.

DrycogX

Type the offset distance along the x-axis for the dry center of gravity of the damper.

DrycogY

Type the offset distance along the y-axis for the dry center of gravity of the damper.

DryCogZ

Type the offset distance along the z-axis for the dry center of gravity of the damper.

WaterWeight

Type the water weight of the damper.

WaterCogX

Type the offset distance along the x-axis for the wet center of gravity of the damper.

WaterCogY

Type the offset distance along the y-axis for the wet center of gravity of the damper.

WaterCogZ

Type the offset distance along the z-axis for the wet center of gravity of the damper.

Width

Type the width of the damper.

DamperLength

Type the length for the damper.

Thickness

Type the thickness for the damper.

FlangeWidth

Type the width of the flange for the damper.

For the remaining properties, (i) indicates an integer corresponding to a nozzle number assigned to the cross section. This method avoids a lengthy listing for all possibilities, like Nozzle(1):CrossSection, Nozzle(2):CrossSection, and Nozzle(3):CrossSection for three possible nozzles. When you type the nozzle properties in the workbook, substitute a number for i to assign the nozzle to the appropriate property.

Nozzle(i):CrossSection

Type the related CrossSection object for the port as listed on the HvacSpec sheet.

Nozzle(i):EndPrep

Type the coded end preparation for Nozzle 1. The AllCodeLists.xls workbook contains mappings between numbers and components. For example, the number 11 in the Nozzle EndPrep column on the ManualDamper sheet corresponds to the flat-face flanged end, as specified in the AllCodeLists.xls workbook.

Nozzle(i):Thickness

Type the thickness of the nozzle port. The number of actual nozzles present on a cableway run can vary.

Nozzle(i):FlangeWidth

Type the flange width for the nozzle.

Nozzle(i):FlowDirection

Type the flow direction for the nozzle.

Nozzle(i):PortDepth

Type the depth of the port for the nozzle.

Nozzle(i):CptOffset

Type the offset value for the component.