Meaning: The width of the branch trench run is large enough to cut one of the trench part's geometry in the header trench run.
Recovery:
-
In the Workspace Explorer, select the header trench run whose trench feature is in error.
-
Click Path .
-
Modify the Sketch 3D path so that the width of the branch trench run is less than the sketch segment of the trench feature.
-
Click Finish on the path ribbon, and then click Finish on the command ribbon.
-OR-
-
In the Workspace Explorer, select the branch trench run that is in error.
-
Click Properties .
The Trench Run Properties dialog box displays.
-
On the Start Cross-Section tab, select Dimensions in the Category box.
-
Decrease the Inside Left Width or Inside Right Width value so that the width of the branch trench run is less than the segment length of the header trench feature.
-
Click OK.
-
Click Finish on the command ribbon.