The Projection values cannot be equal or less than the Chamfer values. Please revise Chamfer and/or Projection value(s) from Trench turn feature property page. - Intergraph Smart 3D - Administration

Intergraph Smart 3D Troubleshooting Reference

PPMProduct
Intergraph Smart 3D
PPMCategory_custom
Administration & Configuration
Version_S3D
12.1(2019)

Meaning: The defined projection values are less than or equal to the chamfer values. Chamfer and projection values are defined in catalog or through the Trench Turn Feature Properties dialog box.

Recovery:

  1. In the Workspace Explorer, select the trench turn feature that is in error.

  2. Click Properties .

    The Trench Turn Feature Properties dialog box displays.

  3. On the General tab, select Dimensions in the Category box.

  4. Change the chamfer or projection values so that projection values are greater than chamfer values.

  5. Click OK.

  6. Click Finish on the command ribbon.