Failed to modify the cutout - Intergraph Smart 3D - Administration

Intergraph Smart 3D Troubleshooting Reference

PPMProduct
Intergraph Smart 3D
PPMCategory_custom
Administration & Configuration
Version_SThreeD_Custom
12.1 (2019)

Meaning: Failed to modify a cutout on the plate. The "cutting tool" was created but when it was applied to actually modify the cut on the plate surface, failure occurred. The opening is invalid.

Recovery:

  1. Try sketching the opening again. The opening must be a closed wire and it must not intersect the plate within its boundaries.

  2. If the problem still exists, report steps taken to your support group along with the sketch being used.