Cope is no longer valid for current member/surface physical orientation - Intergraph Smart 3D - Administration

Intergraph Smart 3D Troubleshooting Reference

PPMProduct
Intergraph Smart 3D
PPMCategory_custom
Administration & Configuration
Version_S3D
12.1(2019)

Meaning: The member or surface has changed position in such a way that the cope is now invalid.

Recovery: Delete and replace the cope.

To delete the cope:

  1. Click Select .

  2. Select Structure in the Locate Filter.

  3. In the Workspace Explorer, expand the member prismatic part branch.

  4. Select the trim feature node under the member part branch to delete.

  5. Click Delete .

Then use Trim Member to replace the cope.