General Tab (Duct Split Feature Properties Dialog Box) - Intergraph Smart 3D - Help

Intergraph Smart 3D HVAC

PPMProductFamily
3D Design and Visualization
PPMProduct
Intergraph Smart 3D
PPMCategory
Help
Version_S3D
12.x(2018)

Sets the general properties of the split.

Duct Run

Specifies the name of the duct run associated with the split. You can select another run from the list if necessary.

<Load More Runs> loads all the runs that belong to the parent system. This option is not available after you load all the runs, or if the parent system contains less than 200 runs.

More displays the Select Duct Run dialog box. Use this option to select a duct run that is associated with a different ducting system. For more information, see Select Duct Run Dialog Box.

Insulation Material

Specifies the material of the insulation.

  • Piping - If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Material box. However, if you manually entered the insulation specification, you must provide a corresponding insulation material as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding material as per the specification.

  • HVAC - If you select Not Insulated, you cannot change the information in Insulation Thickness.

Select More to select an insulation material from the Catalog. To change the options on the list, edit the Insulation Material select list in Catalog.

For more information, see Select Insulation Material Dialog Box.

Insulation Thickness

Specifies the thickness of the insulation.

  • Piping - If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Thickness box. However, if you manually entered the insulation specification, you must provide a corresponding insulation thickness value as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding thickness value as per the specification.

  • HVAC - If you selected Not Insulated in the Insulation Material box, this property is unavailable.

Part

Specifies the part used to split the duct.

Depth Slope

States the slope angle to the depth axis. Depth Slope is displayed only if you select a reference data type that supports slope. Values range from -89 to 89.