These properties are output dimensions populated by the AIR during placement.

The following properties are applicable for U, L, T, and Box Frame types.

IJUAhsFrameSpan::SpanValue - Specifies the span of the frame support. This property is set by the AIR and can be used for reporting purposes or for support validation.

IJUAhsFrameSpan::SpanDefinition - Defines where the span should be measured from. This property sets the definition of SpanValue.

Supported values are as follows for U-Frame and Box Frame are:

Supported values for the L-Frame type are as follows:

Supported values for the T-Frame type are as follows:

IJUAhsFrameLength1::Length1Value - Specifies the length of the first leg after the support has been placed. This property is set by the AIR and can be used for reporting purposes or for support validation.

IJUAhsFrameLength1Def::Length1Definition - Defines where the length should be measured from. This property sets the definition of Length1Value. Supported values are as follows:

For I-Frame:

  1. End of Steel

  2. End of Plate

  3. Pipe Center Line

The following properties are applicable for U-Frame and Box Frame type only.

IJUAhsFrameLength2::Length2Value - Specifies the length of the second leg after the support has been placed. This property is set by the AIR and can be used for reporting purposes or for support validation.

IJUAhsFrameLength2Def::Length2Definition - Defines where the length should be measured from. This property sets the definition of Length2Value.