A BracketByPlane PlateSystem does not have a ReferenceCollection to its symbol - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12.1 (2019)

Message

A BracketByPlane PlateSystem does not have a ReferenceCollection to its symbol.

Severity

Crucial.

Detailed Description

A BracketByPlane PlateSystem requires a ReferenceCollection, which provides links to the symbol information. The ReferenceCollection has relationships to the symbol inputs and other classes required to properly create the plate system and its geometry.

Possible Cause

Unknown.

Possible Impacts

The display of the PlateSystem may not be correct. This problem can affect other related objects.

What You Should Do

  1. Open the model.

  2. In the Molded Forms task, select the BracketByPlane PlateSystem.

  3. Verify that it has a valid symbol and modify it, if necessary. Or, select the object, and perform a re-compute to update it.

  4. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  5. If the object is still posted, contact Smart 3D Support.