SITE-ASSEMBLY-REPORT section - Isogen - Help

Isogen Configuration Help

Language
English
Product
Isogen
Search by Category
Help
I-Configure Version
6.0(2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Defines the output format of the site assembly report. The section heading SITE-ASSEMBLY-REPORT is followed by two sub-section headings:

  • SITE-ASSEMBLY-REPORT-COLUMN-HEADINGS arranges and spaces out the the column headings exactly as they are to appear in the output report file.

SITE-ASSEMBLY-REPORT
SITE-ASSEMBLY-REPORT-COLUMN-HEADINGS
LINEREF DRG ASSY NS BOLT NO ASSY
NO NO DIA OFF ATT1

The column headings look out of line in the example as the space character is narrower than an actual character.

  • SITE-ASSEMBLY-REPORT-DATA-ITEMS specifies the data items included in the report. The table below lists the allowable data items.

    Unique Name

    IDF Record Number

    PIPELINE-REFERENCE

    -6

    DRG

    -

    REVISION

    -8

    BATCH

    -10

    AREA

    -10

    PROJECT-IDENTIFIER

    -9

    PIPING-SPEC

    -11

    NOMINAL-CLASS

    -12

    NOMINAL-RATING

    -12

    DATE-DMY

    -14

    INSULATION-SPEC

    -15

    TRACING-SPEC

    -16

    PAINTING-SPEC

    -17

    PIPELINE-TEMP

    -19

    MISC-SPEC1

    -41

    MISC-SPEC2

    -42

    MISC-SPEC3

    -43

    MISC-SPEC4

    -44

    MISC-SPEC5

    -45

    BOLT-SET-NO

    -

    N.S.

    -

    BOLT-UP-TYPE

    -

    BOLT-DIA

    BOLT-QUANTITY

    -

    TENSION-A

    -

    TENSION-B

    -

    TORQUE-SETTING

    -

    ATTRIBUTE0 to ATTRIBUTE99

    -600 to -699

    ATTRIBUTE100 to ATTRIBUTE199

    -900 to -999

    ASSEMBLY-ATTRIBUTE1 to ASSEMBLY- ATTRIBUTE10

    -190 to -199

An example is shown below:

SITE-ASSEMBLY-REPORT-DATA-ITEMS

'PIPELINE-REFERENCE'  1  L

'DRG'                 10 L

'BOLT-SET-NO'         15 L

'N.S.'                21 L

'BOLT-DIA'            26 L

'BOLT-QUANTITY'       36 L

'ASSEMBLY-ATTRIBUTE1' 45 L

  • You set the Assembly property in the software by selecting each bolt and then setting the value for the Assembly attribute on that bolt.

  • The data items BOLT-UP-TYPE, TENSION-A, TENSION-B, and TORQUE-SETTING require the bolting info file (BOLTING-INFO-OUTPUT section of FDF).

See Also

BOLTING-INFO-OUTPUT section