The PCF attributes that are supported are listed in the table below.

PCF Attribute

Description

AREA / BATCH

Specifies a section of the plant or project. These two attributes are used interchangeably in the PCF.

ATTRIBUTE00 to ATTRIBUTE199

Specifies the user-defined general-purpose pipeline attributes. These attributes can be defined and used for any purpose.

CLIENT-DRAWING-IDENTIFIER

Specifies the user-defined string used to identify, track, or control each individual drawing without using the usual pipeline reference or sheet number identification. Typically, this attribute is output on spool isometric drawings.

DATE-DMY

Specifies the date associated with the pipeline.

EQUIPMENT-REFERENCE

Specifies the name of the equipment. This attribute is mandatory when defining an equipment item.

INSULATION-SPEC

Specifies the default insulation specification.

JACKET-SPEC

Identifies the default piping specification for the components in the pipeline that form part of the jacket.

MISC-SPEC1 to MISC-SPEC5

Indicates the user-defined specification references that hold arbitrary data.

NOMINAL-CLASS

Specifies the pipeline design class.

NOMINAL-RATING

Specifies the pressure rating of the pipeline.

OUTPUT-FILE-NAME

Specifies the filename of the isometric drawing output plot file.

PAINTING-SPEC

Identifies the default painting specification.

PCF-FILE-NAME

Specifies the name of the input piping component file.

PIPING-SPEC

Identifies the primary specification to which the pipeline belongs.

PIPELINE-DRAWING-SEQUENCE
-NUMBER

Specifies the user-defined text string used to identify, track, or control each individual drawing without using the pipeline reference.

PIPELINE-REFERENCE

Specifies the line reference or ID of the pipeline.

PIPELINE-TEMP

Specifies the pipeline operating temperature.

PIPELINE-TYPE

Indicates the type of pipeline construction.

PROJECT-IDENTIFIER

Specifies the project number or name.

REVISION

Indicates the revision identifier for the pipeline.

SPOOL-DRAWING-SEQUENCE
-NUMBER

Specifies the spool sheet isometric drawing sequence number.

SPOOL-NAME / SPOOL-IDENTIFIER / SPOOL-ID

Specifies the name of the spool. These three attributes are used interchangeably in the PCF.

SPOOL-PREFIX

Specifies the string used when creating spool identifiers.

SYSTEM-ISOMETRIC-REFERENCE

Specifies the name of the drawing generated from a system piping object data (POD) file.