Advanced Settings |
Value |
---|---|
Class 1 Branch Flexibility |
False |
Use Schneider |
False |
Use WRC 329 |
False |
Code-Specific Settings |
Value |
---|---|
B31.1 Reduced Z Fix |
True |
B31.1/B31.3 Verified Welding/Contour Tees |
False |
B31.3 Implement Appendix P |
True |
EN-13480/CODETI use In-Plane/Out-Plane SIF |
False |
Ignore B31.1/B31.3 Wc Factor |
True |
No Rft/Wlt in Reduced Fitting SIFs |
False |
Occasional Load Factor |
0.000 |
Pressure Variation in EXP Case |
Default |
Reduced Intersection |
B31.1 (Post 1980) |
General Settings |
Value |
---|---|
Add F/A in Stresses |
Default |
Add Torsion in SL Stress |
Default |
All Cases Corroded |
False |
Allow User's SIF at Bend |
False |
Base Hoop Stress On |
ID |
Default Piping Code |
B31.3 |
New Job Liberal Expansion Stress Allowable |
True |
Use PD/4t |
False |
Yield Stress Criterion |
Max3DShear |
Legacy Settings |
Value |
---|---|
B31.3 Use SL Formulation Para 320 (2010) |
True |
Include Axial Force in Expansion Stress |
Default |
SIF Multiplier for Sustained Stress Index |
0.000 |