As Pipe Dimensions - Isogen - Reference

Isogen Isometric Drawing Options Reference

PPMProduct
Isogen
PPMCategory_custom
Reference
Version_S3D
12.1(2019)
Version_ICP
2.0(2016)
Version_ISOGEN
13.0(2016)

Controls on which side of the pipeline supports are drawn.

  • True draws support dimensions on the same side of pipeline as the normal dimensions.

  • False draws support dimensions on the opposite side of the pipeline to the normal dimensions. When As Pipe Dimensions is set to False, the software ignores any distance set by Standout.

Defines:

Option Switch - 40, Pos 2
I-Configure - Drawing.Dimensions.SuppDimAsDim