Displays Isogen and user-specified attributes that are specific to the flat side of an eccentric reducer.

Attribute names and descriptions

FLAT-DIRECTION

Specifies the direction of the flat side of an eccentric reducer. Valid input data is NORTH, SOUTH, EAST, WEST, UP, or DOWN.

DIRECTION

Provides a user-specified text string that indicates the orientation direction when output as a message on the plotted isometric.

UP 45 NORTH