Displays Isogen and user-specified attributes that are specific to Thickness Measurement Location (TML).
A TML identifies the location on a piping system that requires inspection on a regular basis. Although the TML is basically a message that is output on the isometric drawing, it carries additional attributes relevant to inspection, such as a tag that uniquely identifies the TML and an enclosure style, which controls how Isogen plots the TML.
Attribute names and descriptions
DATA-SOURCE
This is a hidden attribute used by the system and should not be set by the user.
ASSOCIATED
Indicates the pipeline object with which the TML is associated.
NAME
Specifies a unique identifier for the TML.
TEXT
Specifies the supplementary text that is output along with the tag data on the isometric drawing.
SKEY
This is a hidden attribute used by the system and should not be set by the user.
STATUS
Specifies whether the TML is dimensioned. By default, a TML is dimensioned where appropriate unless STATUS is set to UNDIMENSIONED.
ENCLOSURE
Specifies the type of enclosure that Isogen outputs on the isometric drawing with the TML.
MEASUREMENT-TYPE
Specifies the type of measurement. This value must be a text string.
MEASUREMENT-POINTS
Indicates the number of placement points. This value must be a number.
INFORMATION- ATTRIBUTE1 to INFORMATION- ATTRIBUTE100
Specifies up to 100 user-defined information attributes. This value must be a text string.