CL330, CP Type/Termination/Preparation (999) - PDS - Reference Data

Plant Design System (PDS) Reference Data Manager (PD_Data)

PPMProductFamily
3D Design and Visualization
PPMProduct
PDS
PPMCategory
Reference Data

NOTE: Use 2-199 for bolted types; 300-399 for male types and

400-599 for female types. Refer to Reference Data Manager

(PD_DATA) Reference Guide for additional data.

1 = [Blank]

2 = ’FE’ [Flanged end]

Use 11-15 for ends without integral gaskets; 16-19 for ends with

integral gaskets.

10 = ’FFTP (11-19)’ [Flat-face flanged termination type]

11 = ’FFFE’ [Flat-face flanged end]

16 = ’FFFEWG’ [Flat-face flanged end with integral gasket]

Use 21-25 for ends without integral gaskets; 26-29 for ends with

integral gaskets.

20 = ’RFTP (21-29)’ [Raised-face flanged termination type]

21 = ’RFFE’ [Raised-face flanged end]

26 = ’RFFEWG’ [Raised-face flanged end with integral gasket]

Use 31-35 for ends without integral gaskets; 36-39 for ends with

integral gaskets.

30 = ’RJFTP (31-39)’ [RTJ-face flanged termination type]

31 = ’RJFE’ [RTJ-face flanged end]

Use 41-45 for ends without integral gaskets; 46-49 for ends with

integral gaskets.

40 = ’TMFTP (41-49)’ [Tongue/male-face flanged termination type]

41 = ’STFE’ [Small-tongue-face flanged end]

42 = ’LTFE’ [Large-tongue-face flanged end]

43 = ’SMFE’ [Small-male-face flanged end]

44 = ’LMFE’ [Large-male-face flanged end]

Use 51-55 for ends without integral gaskets; 56-59 for ends with

integral gaskets.

50 = ’GFFTP (51-59)’ [Groove/female-face flanged termination type]

51 = ’SGFE’ [Small-groove-face flanged end]

52 = ’LGFE’ [Large-groove-face flanged end]

53 = ’SFFE’ [Small-female-face flanged end]

54 = ’LFFE’ [Large-female-face flanged end]

Use 61-65 for lap-flanged ends without integral gaskets; 66-69 for

lap-flanged ends with integral gaskets.

60 = ’FFLFTP (61-69)’ [Flat-face lap-flanged termination type]

61 = ’FFLFE [Flat-face lap-flanged end]

Use 71-75 for lap-flanged ends without integral gaskets; 76-79 for

lap-flanged ends with integral gaskets.

70 = ’RFLFTP (71-79)’ [Raised-face lap-flanged termination type]

71 = ’RFLFE’ [Raised-face lap-flanged end]

Use 81-85 for lap-flanged ends without integral gaskets; 86-89 for

lap-flanged ends with integral gaskets.

80 = ’RJFLFTP (81-89)’ [RTJ-face lap-flanged termination type]

81 = ’RJLFE’ [RTJ-face lap-flanged end]

Use 91-95 for lap-flanged ends without integral gaskets; 96-99 for

lap-flanged ends with integral gaskets.

90 = ’TMFLFTP (91-99)’ [Tongue/male-face lap-flanged termination type]

91 = ’STLFE’ [Small-tongue-face lap-flanged end]

92 = ’LTLFE’ [Large-tongue-face lap-flanged end]

93 = ’SMLFE’ [Small-male-face lap-flanged end]

94 = ’LMLFE’ [Large-male-face lap-flanged end]

Use 101-105 for lap-flanged ends without integral gaskets; 106-109

for lap-flanged ends with integral gaskets.

100 = ’GFFLFTP (101-109)’[Groove/female-face lap-flanged termination type]

101 = ’SGLFE’ [Small-groove-face lap-flanged end]

102 = ’LGLFE’ [Large-groove-face lap-flanged end]

103 = ’SFLFE’ [Small-female-face lap-flanged end]

104 = ’LFLFE’ [Large-female-face lap-flanged end]

Use 111-115 for ends without integral gaskets; 116-119 for ends

with integral gaskets.

110 = ’FFTBTP (111-119)’[Flat-face thru-bolted termination type]

111 = ’FFTBE’ [Flat-face thru-bolted end]

116 = ’FFTBEWG’ [Flat-face thru-bolted end with integral gasket]

Use 121-125 for ends without integral gaskets; 126-129 for ends

with integral gaskets.

120 = ’RFTBTP (121-129)’[Raised-face thru-bolted termination type]

121 = ’RFTBE’ [Raised-face thru-bolted end]

126 = ’RFTBEWG’ [Raised-face thru-bolted end with integral gasket]

Use 131-135 for ends without integral gaskets; 136-139 for ends

with integral gaskets.

130 = ’RJTBTP (131-139)’[RTJ-face thru-bolted termination type]

131 = ’RJTBE’ [RTJ-face thru-bolted end]

Use 141-145 for ends without integral gaskets; 146-149 for ends

with integral gaskets.

140 = ’MRJTBTP (141-149)’[Male RTJ-face thru-bolted termination type]

146 = ’MRJTBEWG’ [Male RTJ-face thru-bolted end with integral gasket]

Use 151-155 for ends without integral gaskets; 156-159 for ends

with integral gaskets.

150 = ’FFTBCSTP (151-159)’[Flat-face thru-bolted-with-cap-screws termination ty

151 = ’FFTBCSE’ [Flat-face thru-bolted-with-cap-screws end]

156 = ’FFTBCSEWG’ [Flat-face thru-bolted-with-cap-screws end with integ

Use 161-165 for ends without integral gaskets; 166-169 for ends

with integral gaskets.

160 = ’RFTBCSTP (161-169)’[Raised-face thru-bolted-with-cap-screws termination

161 = ’RFTBCSE’ [Raised-face thru-bolted-with-cap-screws end]

166 = ’RFTBCSEWG’ [Raised-face thru-bolted-with-cap-screws end with int

Use 171-175 for ends without integral gaskets; 176-179 for ends

with integral gaskets.

170 = ’RJTBCSTP (171-179)’[RTJ-face thru-bolted-with-cap-screws termination typ

171 = ’RJTBCSE’ [RTJ-face thru-bolted-with-cap-screws end]

Use 181-185 for ends without integral gaskets; 186-189 for ends

with integral gaskets.

180 = ’FFFTBTP (181-189)’[Flat-full-face thru-bolted termination type]

181 = ’FFFTBE’ [Flat-full-face thru-bolted end]

186 = ’FFFTBEWG’ [Flat-full-face thru-bolted end with integral gasket]

190 = ’MJTP (190-199)’[Mechanical joint termination type]

191 = ’MJE’ [Mechanical joint end]

300 = ’MTP (301-399)’[Male termination type]

Use 301-309 for welded ends only

301 = ’BE’ [Beveled end]

302 = ’OLET’ [Olet beveled end]

Use 311-319 for welded ends only

311 = ’TBE’ [Tapered and beveled end]

321 = ’MFE’ [Male flared end]

331 = ’MTE’ [Male threaded end]

341 = ’MGE’ [Male grooved end]

351 = ’MQCE’ [Male quick connect end]

355 = ’MCE’ [Male clamp end]

361 = ’MFRE’ [Male ferrule end]

371 = ’MHE’ [Male hose end]

381 = ’SPE’ [Spigot end]

Use 391-399 for welded ends only

391 = ’PE (391-399)’[Plain end]

393 = ’3"FFPE’ [Plain end, 3" field fit]

395 = ’6"FFPE’ [Plain end, 6" field fit]

400 = ’STP (401-409)’[Socket termination type]

401 = ’SE’ [Socket end]

Use 421-429 for welded ends only

420 = ’SWTP (421-429)’[Socketwelded termination type]

421 = ’SWE’ [Socketwelded end]

440 = ’FTTP (441-449)’[Female threaded termination type]

441 = ’FTE’ [Female threaded end]

460 = ’FGTP (461-469)’[Female grooved termination type]

461 = ’FGE’ [Female grooved end]

470 = ’FCTP (471-479)’[Female clamp termination type]

471 = ’FCE’ [Female clamp end]

480 = ’FQCTP (481-489)’[Female quick connect termination type]

481 = ’FQCE’ [Female quick connect end]

500 = ’FFRTP (501-509)’[Female ferrule termination type]

501 = ’FFRE’ [Female ferrule end]

520 = ’FHTP (521-529)’[Female hose termination type]

521 = ’FHE’ [Female hose end]

540 = ’BLTP (541-549)’[Bell end termination type]

541 = ’BLE’ [Push-on bell end]

542 = ’MJBE’ [Mechanical joint bell end]

590 = ’HTP (581-599)’[Hole end termination type]

Use 591-599 for welded ends only

591 = ’HCE’ [Circular hole end]

600 = ’NTP (600-605)’[Null termination type]

601 = ’NE’ [Null end]

650 = ’UDTP (651-659)’[User defined termination type]

651 = ’UD’ [User defined end] (When a "UD"

preparation end is detected by the

system in the piping materials

class, it will prompt the User to define

the actual CP preparation to use. The

value provided by the User will be used

for initial placement of the component

as well as for subsequent recreations of

the piping system.)