Open the Piping Specification.xls workbook.
-
Select the CorrosionAllowance sheet.
-
Select a row after the Start keyword but before the End keyword, and click Insert > Row.
-
In the Spec Name column, type the name of the piping materials class.
-
In the Materials Category column, enter the materials code for which you are defining corrosion allowance.
-
In the Fluid Code column, enter the fluid code for which you are defining corrosion allowance.
-
In the Corrosion Allowance column, specify the corrosion allowance for the specified material and fluid codes. Be sure to include the units of measurement, in or mm, when specifying this value.
-
Save the Piping Specification.xls workbook.
-
The piping materials class must be defined on the PipingMaterialsClassData sheet.
-
Valid material codes are defined in the AllCodeLists.xls workbook on the MaterialGrade sheet in the Codelist Number column.