HVAC Translation Maps - Intergraph Smart 3D - 2019 - Administration

Intergraph Smart 3D PDMS Design and Data Exchange

Language
English
Product
Intergraph Smart 3D
Search by Category
Administration & Configuration
Smart 3D Version
12.1 (2019)

Use the HVAC translation mapping sheets in the PDMSS3DImportMapping.xls workbook to map PDMS HVAC attributes to the corresponding Smart 3D HVAC properties. Before importing PDMS HVAC model data to Smart 3D, modify these sheets to ensure that the following criteria are met:

  • All PDMS HVAC specifications that present in the PDMS DATAL or .att file are mapped to corresponding Smart 3D specifications.

  • All components in PDMS are mapped to corresponding Smart 3D HVAC components.

  • All PDMS HVAC specifications that are present in the PDMS DATAL or .att file are mapped to the correct Smart 3D materials.

After you complete all of the mapping in the PDMSS3DImportMapping.xls workbook, run PDMS Import Validation to validate the mapping data in the workbook. Resolve any missing entries reported by the validation tool. For more information, see PDMS Import Validation.

HVACGlobalsMap

Defines the global settings for importing PDMS .att files for the HVAC discipline. For more information, see HVACGlobalsMap.

CPDuctRunMap

Maps PDMS BRANCH attributes, such as HBORE and PSPE to the Smart 3D HVAC schema duct run class properties. For more information, see CPDuctRunMap.

CPDuctingSystemMap

Maps PDMS PIPE attributes (when HVAC BRANCH attributes are included) to the Smart 3D HVAC schema’s ducting system properties. For more information, see CPDuctingSystemMap.

DuctComponentAttrsMap

Maps PDMS HVAC component attributes, such as FTUBE, to the Smart 3D HVAC schema component attributes or to UserAttributes. For more information, see DuctComponentAttrsMap.

DuctFittingAttrsMap

Maps PDMS HVAC fittings and other PDMS component attributes (excluding FTUBE) to Smart 3D HVAC schema fitting attributes, such as BendRadius, or to UserAttributes <Property>. For more information, see DuctFittingAttrsMap.

HVACAdditionalAttsMap

Maps any additional attributes that are required by Smart 3D HVAC PartNumbers (that is, the part class of the Smart 3D component and geometry type). You can also use this sheet to map the design parameters of a specific PDMS HVAC component (in the format DESP[2]) to the relevant Smart 3D HVAC schema component or fitting dimensional data. Mapping design parameters requires that you specify the Smart 3D Interface and property (in the format DimensionalData.<InterfaceName>.<Property>. For more information, see HVACAdditionalAttsMap.

HVACClassMap

Maps the supported HVAC classes between PDMS and Smart 3D. This is the main mapping sheet for the HVAC discipline. For more information, see HVACClassMap.

HVACCrossSectionMap

Maps the PDMS HVAC component HCON value in the PDMS DATAL or .att file to the Smart 3D HVAC cross-section codelist value. For more information, see HVACCrossSectionMap.

HVACRunSpecMap

Maps the PDMS HVACRun specification to Smart 3D HVAC specification. For more information, see

HVACRunMaterialMap

Maps the PDMS HVACRun specification to Smart 3D material values. This mapping also sets the Material property for the Smart 3D HVAC schema duct run class properties. For more information, see HVACRunMaterialMap.

S3DHVACXMLPartTypeMap

Maps the PDMS HVAC elements, such as REDUCER, FTUBE, and ELBOW, that are present in the DATAL or .att file to relevant Smart 3D HVAC components or fittings. For more information, see S3DHVACXMLPartTypeMap.

SPREFS3DHVACIdentifierPttrnMap

Maps PDMS HVAC component SPRE attributes to relevant Smart 3D HVAC part numbers. For more information, see SPREFS3DHVACIdentifierPttrnMap.

PDMSS3DFileConstants

Defines the PDMS constants that are present in the HVAC .att file to relevant Smart 3D values. These Smart 3D constants are used in the code. For more information, see PDMSS3DFileConstants.