Define Auto Router Pipe Rack Spacing - Intergraph Smart 3D - Help

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
11 (2016)
  1. In the tree view, click Piping > Piping Specification > Piping Materials Classes.

  2. In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Auto Router Pipe Rack Spacing Rule.

  3. Click the Insert Row Command to insert a blank row in the grid view.

  4. In the SpecName column, type the Piping Materials Class to define pipe rack spacing

  5. In the Nominal Diameter From column, type the lower bound of piping diameter.

  6. In the Nominal Diameter To column, type the upper bound of piping diameter.

  7. In the NPD Units column, type the units for Nominal Diameter From and Nominal Diameter To columns.

  8. In the Branch Gap column, type the separation between adjacent branches connecting to the same header.

  9. In the Joint Air Gap column, type the separation between adjacent joints.

  10. In the Pipe Air Gap column, type the separation between adjacent pipes of the same NPD.

The Auto Router Pipe Rack Spacing sheet in the workbook corresponds to the Auto Router Pipe Rack Spacing Rule node in the Catalog task. See Piping Reference Data.