Define Field Lining Thickness - Intergraph Smart 3D - Help

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
11 (2016)
  1. In the tree view, click Piping > Piping Specification > Piping Materials Classes.

  2. In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Field Lining Thickness Rule.

  3. Click the Insert Row Command to insert a blank row in the grid view.

  4. In the Nominal Piping Diameter From column, type the lower boundary for nominal pipe diameter.

  5. In the Nominal Piping Diameter To column, type the upper boundary for nominal pipe diameter.

  6. In the Nominal Piping Diameter Units column, type the units for the NPD. For example, type mm or in.

  7. In the Liner Thickness Inside Diameter column, enter the thickness of the lining material at the inside diameter of field-lined fittings.

  8. In the Liner Thickness on Face of Flange column, enter the thickness of the lining material at the face of the flange at any field-lined bolted fittings.

The Field Lining Thickness sheet in the Piping Material Class.xls workbook corresponds to the Field Lining Thickness Rule node in the Catalog task. See Piping Reference Data.