Define Flared Pipe Per Spec - Intergraph Smart 3D - Help

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
12 (2018)
  1. In the tree view, click Piping > Piping Specification > Piping Materials Classes.

  2. In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Flared Pipe Per Spec Rule.

  3. Click the Insert Row Command to insert a blank row in the grid view.

  4. In the Spec Name column, type the name of the piping material class.

  5. In the Nominal Piping Diameter column, enter the pipe diameter for which the flared pipe information applies.

  6. In the Nominal Piping Diameter Units column, type the units for the NPD. For example, type mm or in.

  7. In the Schedule Thickness column, enter the schedule thickness short description or code for the pipe.

  8. In the Lap Length column, enter the extra length to add to the pipe.

  9. In the Lap Thickness column, enter the thickness of the flared lip.

.The Flared Pipe sheet in the workbook corresponds to the Flared Pipe Per Spec Rule node in the Catalog task. See Piping Reference Data.