Define Conduit Nominal Diameters - Intergraph Smart 3D - Help

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
12 (2018)
  1. Click the Grid View Command in the ribbon.

  2. In the tree view, click Conduit > Specifications > <spec name> > Conduit Rules > Permissible Nominal Conduit Diameters Rule.

  3. Click the Insert Row Command to insert a blank row in the grid view.

  4. In the Nominal Diameter column, type the nominal diameters to define in your conduit materials class.

  5. In the Unit Type column, type the units for your nominal diameter. For example, type mm or in.

  6. Click the Save Command Save.