  1. In the tree view, click Piping > Piping Specification > Model Rules > Preferred Cap Screw Length.

  2. Click the Insert Row Command to insert a blank row in the grid view.

  3. In the Bolt Diameter From column, specify the beginning bolt diameter for the range of bolt diameters that are to use the preferred bolt length.

  4. In the Bolt Diameter To column, specify the ending bolt diameter for the range of bolt diameters that are to use the preferred bolt length.

  5. In the Bolt Diameter Increment column, type the value by which to increment the bolt diameter.

  6. In the Materials Grade column, type the material grade code for the bolt.

  7. Define the preferred bolt length information in the remaining columns.