Multiple Can Design - CAESAR II - Reference Data

CAESAR II Applications Guide

Language
Русский
Product
CAESAR II
Search by Category
Reference Data
CAESAR II Version
12

Enter the number of hangers or cans as a positive number in the No. of Hangers at Location box.

Placing a negative number in that field allows CAESAR II to design up to that number of hangers at the location.

All other hanger design parameters are still active.

Example

Trapeze Hanger Assembly

Power Piping Springs

Allowable Load Variation:15%

Rigid Support Displacement Criteria: 0.05 inches

The software designs up to three cans at the support if the load is too high for a single or double can configuration.