Hub Properties (Flange) - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Hub Type

Defines the construction of the flange hub. Select Tapered or No Hub for all flange types except Blind G.3-9.

The software sets the hub type to No Connected Shell when you select Blind G.3-9 for Flange Type.

Hub Length (RlH/RlHm)

Adapted from Figure 4, EN 1591-1:2001+A1, Flanges and their joints - Design rules for gasketed circular flange connections - Part 1: Calculation method

Defines IH, the length of the hub.

If you use Flange Dimension Lookup , the software defines a value for this field.

Hub Large End Thk (e2/e2m)

Adapted from Figure 4, EN 1591-1:2001+A1, Flanges and their joints - Design rules for gasketed circular flange connections - Part 1: Calculation method

Defines e2, the minimum wall thickness at the thick end of the hub.

If you use Flange Dimension Lookup , the software defines a value for this field.

Hub Small End Thk (e1/e1m)

Adapted from Figure 4, EN 1591-1:2001+A1, Flanges and their joints - Design rules for gasketed circular flange connections - Part 1: Calculation method

Defines e1, the minimum wall thickness at the thin end of the hub.

If you use Flange Dimension Lookup , the software defines a value for this field.

Hub Thick End Avg Diameter (d2/d2m)

Adapted from Figure 4, EN 1591-1:2001+A1, Flanges and their joints - Design rules for gasketed circular flange connections - Part 1: Calculation method

Defines d2, the average diameter of the thick end of the hub.

Hub Thin End Avg Diameter (d1/d1m)

Adapted from Figure 4, EN 1591-1:2001+A1, Flanges and their joints - Design rules for gasketed circular flange connections - Part 1: Calculation method

Defines d1, the average diameter of the thin end of the hub.